KINX IDC network is the first Layer 2 type neutral Internet exchange Point in Korea and it's designed and being operated based on KINX network operation know-how. It has the following features.

Optimized network environment directly connected to IX network in which approx. 30 ISPs are inter-networked
Efficient processing of large amount of traffic based on duplication of core backbone network and Giga backbone network configuration
Continued monitor of the usage rate of key network points to maintain optimized condition
24-hour customer system monitoring by professionals with rich experience
Scalable network for future network expansion
Optimized configuration of customer service by providing various On Site added service

1. Domestic and international internetworking network
KINX IDC guarantees the most efficient line connection for enormous number of lines by connecting to KNIX, which is a core of traffic in Korea , where domestic top-tier ISPs and key content providers are inter-networked. All the domestic infrastructure communication providers and optical termination equipment of international companies are located in KNIX. KINX IDC is inter-networked with Korea Computerization Agency and 2Giga for optimized national public network connection environment.

2. Center facility

1) General building
Anti-earthquake design considering domestic anti-earthquake criteria
Ground construction in accordance with international regulations
Monitoring by CCTV camera system
Design of individual lock device per Half Rack unit
Strict identification management by adopting individual ID and fingerprint recognition system

2) Network infrastructure
Double cable tray structure
Above cabinet (ceiling tray) : optical cable, LAN, communication pipe
Below Floor (floor tray) : power line pipe (AC)
Introduced optical termination equipment for 7 domestic communication providers

3) Power
Generator : Rated capacity 1250KVA/1000KW, Quantity 2EA
UPS : Rated capacity 400KVA X 2EA Parallel operation
Charged battery : Rated capacity 2V, 400AH, Quantity 768CELL (192CELL X 2set X 2Set)

4) Constant temperature and humidity, fire

Maintain temperature/humidity 22 ¡Æ C/45% in the center
Pipe system for cooling water
Automatic alarm function for water leak by implementing water leak detection cabling
Seamless ventilation system by installing Access Floor below Rack and Cable Tray over ceiling

5) Security

24-hour 365-day network monitoring system by full-time professionals
Perfect triple building security system (guest control, CCTV, fingerprint recognition system)

3. Detail facility

1) UPS
A system supplying optimized voltage to customer's equipment
Supply more than 3-hour of stable power during electricity failure

2) Precision air conditioner

A system to maintain internetworking company's equipment at its optimized condition
Maintain optimum operation environment (24x7x365, temperature 20-25 ¡É , humidity 40-60%)
Large capacity system which can afford 300% of internetworking center

3) Generator

A generator which can start its operation within 45 sec. when there is electricity failure from Korea Electric Power Corporation

4) Extinguisher

A system extinguishing fire without damaging customer's equipment when fire occurs
Duplicate system for stable fire suppression

5) Secure rack

Can be used either Open Rack or Cabinet
Implementation of equipment security with individual lock device per Half Rack unit

6) Power filtering

Protect equipments from thunderbolt, Surge, Transient, and abnormal voltage
Protect equipments by supplying stable power